Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
371
3
110.16
Input min. amount
Absolute value of lower limit of the active ramp generator input (
If the input value is exactly 0%, the limit is set to the positive value of
Parameter value with 32-bit resolution.
Standardization:
100%
=
Maximum drive speed (
, [rpm])
The result of this limiting forms the effective input value for the ramp generator.
If the standard values of Parameters
and
remain set, no limiting
takes place and the ramp input receives values between -100% and +100%.
Figure 93:
Absolute value of min. / max. input
110.17
Input 32 bit additive
Additional ramp function generator input value with 32 bit resolution.
The additional set value is used independent of the input selection in parameter
bit 5. This additional set value is always added to the defined main set value (
or
), to a total set value. Subsequent to this, checking is made using the input value
limitation (
Standardization:
100%
=
Maximum drive speed (
, [rpm])
110.20
Controlled stop time
Delay ramp for the controlled stop.
The set time in this parameter applies to a 100% change of the set value.