Controllers
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
Baumüller Nürnberg GmbH
498
3.7
3.7.6.3 Description of the Flux Controller parameters
146.10
Kp flux controller
Proportional gain of the flux controller.
The flux controller is switched off, if the proportional gain is less or equal to 0.1.
146.11
Tn flux controller
Reset time of the flux controller [ms]
146.12
Limit magnetizing current
Limitation of the flux controller’s output [A]
146.15
Actual flux current
Flux current [A]
146.18
Integral term flux controller
Integral term of the flux controller
Number
Name
Type
Min
Max
Default Value
Unit
Factor
R
ead o
n
ly
St
o
ra
g
e
D
S
Supp
ort
C
yclic W
rite
Ax
is
-i
nd
e
p
e
n
de
n
t
146.10
Kp flux controller
FLOAT
0
1e9
0
1/s
1:1
X
146.11
Tn flux controller
FLOAT
0
10000
1000
ms
1:1
X
146.12
Limit magnetizing cur-
rent
FLOAT
0
1e9
10
A
1:1
X
146.15
Actual flux current
FLOAT
-1e9
1e9
0
A
1:1
X
146.18
Integral term flux con-
troller
FLOAT
-1e9
1e9
0
A
1:1
X