Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
275
3
165.4
Bit mode
The bit logic and the bit number of the source parameter are set in this parameter.
This is a RECORD type parameter (array).
165.5
Logic functions
are combined using logic functions via these parameters. Bi-
nary logic functions of adjacent bits of the configured status can be processed.
Refer to the appropriate bit of
for the results of logic function.
The logic structure is described in chapter
The logic function is activated by entering a value between 1 and 6.
Bit No.
Meaning
4 … 0
Bit number
7 … 5
Reserved
8
Bit Logic:
0 = positive logic;
selected bit is copied unchanged into the configured status
1 = negative logic;
selected bit is copied inverted into the configured status
15 … 9
Reserved
Index
Meaning
0
Bit number and bit logic for status bit 0 of
1
Bit number and bit logic for status bit 1 of
…
…
15
Bit number and bit logic for status bit 15 of
Value
Meaning
0
Logic function is switched off.
1
AND operation
2
OR operation
3
XOR operation (exclusive OR operation)
4
NAND operation (NOT – AND)
5
NOR operation (NOT – OR)
6
XNOR operation (exclusive NOT – OR)