Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
225
3
1
Activation channel measurement negative edge
(Enc1TrDi1NegValRev/Enc1TrDi1NegValPhi)
0: switch off
1: switch on
2
Trigger frequency
0: one-time trigger
a new measure does not occur until measuring encoder has been reac-
tivated with P124.2
1: Continuous triggering
Measurements always occur; however, within a sampling cycle of the
module (1 ms), only the first event will be triggered.
3…5 Measurement "Encoder 1 with Trigger digital input TP2"
3
Activation channel measurement positive edge
(Enc1TrDi2PosValRev/Enc1TrDi2PosValPhi)
0: switch off
1: switch on
4
Activation channel measurement negative edge
(Enc1TrDi2NegValRev/Enc1TrDi2NegValPhi)
0: switch off
1: switch on
5
Trigger frequency
0: one-time trigger
a new measure does not occur until measuring encoder has been reac-
tivated with P124.2
1: Continuous triggering
Measurements always occur; however, within a sampling cycle of the
module (1 ms), only the first event will be triggered.
6…
12
Measurement "Encoder 1 with Trigger Zero Pulse"
6
Activation channel measurement positive edge
(Enc1TrZpPosValRev/Enc1TrZpPosValPhi)
0: switch off
1: switch on
7
Activation channel measurement negative edge
(Enc1TrZpNegValRev/Enc1TrZpNegValPhi)
0: switch off
1: switch on
8
Reserved
9
Activation Qualification with digital input
0: Qualification off
1: Qualification on
10
Selection digital input for qualification
0: Qualification zero pulse with digital input TP1
1: Qualification zero pulse with digital input TP2
Bit
Meaning