Slip frequency actual temperature
(This is relevant at asynchronous motors with an encoder if the temperature monitoring
is active,
Slip frequency of the motor at nominal torque current and nominal flux (magnetic flux =
100%) according to the motor temperature actual value
culated by the temperature adaption characteristic and is used to determine the "Slip pre-
set value" (
). See
Temperature adaption slip frequency
19.32
Rotor time constant
Display of the rotor time constant for the asynchronous motor; required for flux control.
The value is calculated from the magnetic current
, the nominal current
and the slip frequency cold
Has no significance for synchronous motors.
19.50
Notch position O.K.
19.51
Current ref. for notch position detection
Current for the notch position detection.
Standardization:
100%
=
Motor Nominal current
Bit
Meaning
0
Plausibility O.K. (Absolute encoder present)
1
Notch position search active
2
Notch position search ended
3
Notch position search failed or plausibility error
15 ... 4
Reserved