![Baumuller b maXX BM5800 Parameter Manual Download Page 111](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380111.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
111
3
138.4
Quadrant hysteresis Iq limit
Hysteresis for current and speed for assessing the operating quadrants.
Standardization:
100%
=
Motor nominal torque current
or
100%
=
138.5
Motor quadrant
Display of the currently determined quadrant, using the current speed, the instantaneous
current and the set hysteresis.
The following diagram illustrates the definition:
Figure 39:
Definition of the quadrants
138.6
Iq upper limit
Display of the currently determined upper limit for the instantaneous current [in A].
138.7
Iq lower limit
Display of the currently determined lower limit for the instantaneous current [in A].
138.8
Bitmask of external drive current limit
Display of external sources of the drive current limit as a bit string.
A 1 in the corresponding bit position means that the limit is active.
If several bits are set, the smallest limit takes effect.