![Baumuller b maXX BM5800 Parameter Manual Download Page 101](http://html.mh-extra.com/html/baumuller/b-maxx-bm5800/b-maxx-bm5800_parameter-manual_2711380101.webp)
Description of the Software Modules and Parameters
Parameter manual
b maXX
BM5800
Document No.: 5.16029.03
101
3
107.23
Friction moment
Display of the motor friction moment. The value displayed is read from motors with an
electronic identification plate and is for information only.
107.24
Attenuation factor
Display of the motor attenuation factor, Kd. The value displayed is read from motors with
an electronic identification plate and is for information only.
107.25
Max speed electr.
The maximum speed of the motor, regardless of the mechanical configuration. The value
displayed is read from motors with an electronic identification plate and is for information
only.
107.26
Max speed mech.
Setting of the maximum speed of the motor that is permissible in the mechanical config-
uration used. The mechanical maximum speed can at most equal the electrical maximum
speed.
The smaller value of max. speed mech.
and of speed limit
acts as
limitation in the operating modes 1, 5, 6 and -4. For details, refer to
.
Additionally it limits the settings of the standardization for the ramp function generator in
operating modes 2 and -3. For details, refer to
The parameter can be changed in the inhibited state, only.
107.27
Max temperature
Switch-off threshold of the motor temperature monitor.
CAUTION!
If the motor operates with higher speed than the maximum speed, the motor may be
damaged mechanically.