14-8 BESTCOMS
Software BE1-CDS220
Global Security
This screen (Figure 14-9) allows you to set up password security. Each of three communication ports and
the four functional areas (Global, Settings, Reports, and Control) are protected with password security.
This allows the user to customize password protection for any or all ports. For example, you could allow
technicians to have global access (sometimes called a fourth level of access) to all three functional areas
via the front port. You could also restrict the rear port, which is connected to a modem to read-only
access.
If you select show passwords and notice that the default passwords have not been changed, then you
may change all four passwords. If the global password has been changed, a dialog box appears
explaining that you must enter the global password to enable viewing and editing the existing passwords.
After entering the global password, the passwords and enable boxes appear. You may then make
changes in any or all areas. Clicking a box for a specific communication port toggles the functional area
for that port either ON or OFF. Notice that the front panel human-machine interface (HMI) and
communications port zero are combined and considered as one.
Figure 14-9. General Operation Screen, Global Security Tab
Communication
This screen (Figure 14-10) allows the user to set or change additional communication parameters that
cannot be set with the toolbar Communication, Configure screen. Baud Rate has the pull-down menu
while Reply and Handshaking are either enabled or disabled. Page Length can be stepped up or down
one page at a time using the Up or Down arrow buttons. Address can be stepped up or down to change
the address except for Com Port 0 Front. This address is always A0 and cannot be changed. If the relay
has Modbus
, the Com Port 2, Modbus Settings panel appears on the General Operation screen,
Communication tab. This panel allows the user to select the Precision Format, Parity, Remote Delay
Time, Stop Bits, and Password. For more information on these parameters, see the Modbus Instruction
Manual (Basler Electric part number 9365200992).
Summary of Contents for BE1-CDS220
Page 2: ......
Page 10: ...viii Introduction BE1 CDS220 This page intentionally left blank...
Page 36: ...ii Quick Start BE1 CDS220 This page intentionally left blank...
Page 48: ...ii Input And Output Functions BE1 CDS220 This page intentionally left blank...
Page 66: ...iv Protection and Control BE1 CDS220 This page intentionally left blank...
Page 112: ...ii Metering BE1 CDS220 This page intentionally left blank...
Page 116: ...5 4 Metering BE1 CDS220 This page intentionally left blank...
Page 166: ...ii BESTlogic Programmable Logic BE1 CDS220 This page intentionally left blank...
Page 176: ...7 10 BESTlogic Programmable Logic BE1 CDS220 This page intentionally left blank...
Page 234: ...8 56 Application BE1 CDS220 This page intentionally left blank...
Page 236: ...ii Security BE1 CDS220 This page intentionally left blank...
Page 240: ...9 4 Security BE1 CDS220 This page intentionally left blank...
Page 242: ...ii Human Machine Interface BE1 CDS220 This page intentionally left blank...
Page 256: ...10 14 Human Machine Interface BE1 CDS220 This page intentionally left blank...
Page 258: ...ii ASCII Command Interface BE1 CDS220 This page intentionally left blank...
Page 422: ...14 32 BESTCOMS Software BE1 CDS220 This page intentionally left blank...
Page 424: ...ii Time Current Characteristics BE1 CDS220 This page intentionally left blank...
Page 452: ...ii Terminal Communication BE1 CDS220 This page intentionally left blank...
Page 456: ...C 4 Terminal Communication BE1 CDS220 This page intentionally left blank...
Page 458: ...ii Settings Calculations BE1 CDS220 This page intentionally left blank...
Page 475: ......