To edit the automatic scrolling list using BESTCOMS, select General Operation from the Screens pull-
down menu. Then select the HMI Display tab. Refer to Figure 10-10. The screen numbers listed exhibit
the default scrolling list. The list of numbers on the right represents the screen numbers and the order in
which they will be displayed when automatic scrolling begins. The number closest to the top will be
displayed first. The four buttons on the screen can be used to add or remove screens from the list. They
can also be used to change a selected screens position in the list.
Figure 10-10. General Operation Screen, HMI Display Tab
To add a screen to the list, select the screen on the HMI simulation by clicking the mouse pointer on the
arrows. Select the Add-> button to add the screen to the list.
Alternately, these settings may be made using the SG-SCREEN ASCII command.
HMI OPERATIONS
The following paragraphs describe how the HMI is used to set and control relay functions.
Entering Settings
Settings for protection functions can be edited from menu branch 5, PROTECTION of the LCD HMI.
Control functions can be edited from menu branch 2, CONTROL. Settings for general and reporting
functions can be edited from menu branch 6, GENERAL SETTINGS. To edit a setting using the manual
scrolling pushbuttons, perform the following procedures:
1. Scroll to the screen that displays the function to be edited.
2. Press
the
Edit pushbutton to gain access. If password security has been initiated for settings, you
will be prompted to enter the appropriate password. See the paragraphs, Entering Passwords, for
details on entering passwords from the HMI. Once access has been gained, the Edit LED will be
lighted and a cursor will appear in the first settings field on the screen.
3. Press
the
UP or DOWN scrolling key to select the desired setting. Some settings require entering
a number one character at a time. For example, to enter a 51 pickup as 7.3 amps, you would
press the UP pushbutton until the 7 is showing. Then, press the RIGHT pushbutton to move the
cursor over and press the UP pushbutton until the “.” is showing. Then, press the RIGHT
pushbutton to move the cursor over and press the UP pushbutton until the 3 is showing. Other
settings require scrolling through a list of selections. For example, you would move the cursor
over to the CRV field and then scroll through a list of available TCC curves.
Summary of Contents for BE1-CDS220
Page 2: ......
Page 10: ...viii Introduction BE1 CDS220 This page intentionally left blank...
Page 36: ...ii Quick Start BE1 CDS220 This page intentionally left blank...
Page 48: ...ii Input And Output Functions BE1 CDS220 This page intentionally left blank...
Page 66: ...iv Protection and Control BE1 CDS220 This page intentionally left blank...
Page 112: ...ii Metering BE1 CDS220 This page intentionally left blank...
Page 116: ...5 4 Metering BE1 CDS220 This page intentionally left blank...
Page 166: ...ii BESTlogic Programmable Logic BE1 CDS220 This page intentionally left blank...
Page 176: ...7 10 BESTlogic Programmable Logic BE1 CDS220 This page intentionally left blank...
Page 234: ...8 56 Application BE1 CDS220 This page intentionally left blank...
Page 236: ...ii Security BE1 CDS220 This page intentionally left blank...
Page 240: ...9 4 Security BE1 CDS220 This page intentionally left blank...
Page 242: ...ii Human Machine Interface BE1 CDS220 This page intentionally left blank...
Page 256: ...10 14 Human Machine Interface BE1 CDS220 This page intentionally left blank...
Page 258: ...ii ASCII Command Interface BE1 CDS220 This page intentionally left blank...
Page 422: ...14 32 BESTCOMS Software BE1 CDS220 This page intentionally left blank...
Page 424: ...ii Time Current Characteristics BE1 CDS220 This page intentionally left blank...
Page 452: ...ii Terminal Communication BE1 CDS220 This page intentionally left blank...
Page 456: ...C 4 Terminal Communication BE1 CDS220 This page intentionally left blank...
Page 458: ...ii Settings Calculations BE1 CDS220 This page intentionally left blank...
Page 475: ......