BE1-CDS220 Installation
12-3
•
Figures 12-2 through 12-4 show the overall dimensions for the MX case with rack mount
brackets. The dimensions shown in Figure 12-2, Front View, Optional HMI, are the same with the
standard HMI.
•
Figures 12-5 through 12-7 show the overall dimensions of the MX case with a panel mounting
flange. The examples shown in these figures are vertical panel mounting configurations.
Horizontal panel mounting configurations have the same dimensions except that they are in a
horizontal arrangement. Figure 12-6 shows the locations of holes for the Basler, GE, and
Westinghouse unit relay cases (vertical panel mount only). Figure 12-8 (horizontal or vertical
panel mount) shows the locations of the studs used for mounting.
•
Figure 12-9 shows the panel cutout and panel drilling dimensions for the MX case vertical panel
mounting configuration. Horizontal panel mounting configurations have the same panel cutout
and panel drilling dimensions except that they are in a horizontal arrangement.
Vertical and horizontal configurations are functionally the same with some controls and indicators
relocated. All dimensions given on the above listed drawings are dimensioned in inches (millimeters).
18.34
(482.6)
(465.8)
.625
(15.88)
2.25
(57.15)
5.22
(132.6)
.625
(15.88)
.281 x .406 SLOT (8 PLC'S)
.860
(21.84)
D2837-01
07-07-99
19.00
Figure 12-2. MX Case, 19-Inch Rack Mount, Front View, Overall Dimensions, Optional HMI
Note: The dimensions are the same for the standard HMI.
.125 TYP.
(3.18)
1.000 (25.4)
2.337
(59.36)
D2837-02
01-08-99
14.32
(363.73)
Figure 12-3. MX Case, 19-Inch Rack Mount, Top View, Overall Dimensions
Summary of Contents for BE1-CDS220
Page 2: ......
Page 10: ...viii Introduction BE1 CDS220 This page intentionally left blank...
Page 36: ...ii Quick Start BE1 CDS220 This page intentionally left blank...
Page 48: ...ii Input And Output Functions BE1 CDS220 This page intentionally left blank...
Page 66: ...iv Protection and Control BE1 CDS220 This page intentionally left blank...
Page 112: ...ii Metering BE1 CDS220 This page intentionally left blank...
Page 116: ...5 4 Metering BE1 CDS220 This page intentionally left blank...
Page 166: ...ii BESTlogic Programmable Logic BE1 CDS220 This page intentionally left blank...
Page 176: ...7 10 BESTlogic Programmable Logic BE1 CDS220 This page intentionally left blank...
Page 234: ...8 56 Application BE1 CDS220 This page intentionally left blank...
Page 236: ...ii Security BE1 CDS220 This page intentionally left blank...
Page 240: ...9 4 Security BE1 CDS220 This page intentionally left blank...
Page 242: ...ii Human Machine Interface BE1 CDS220 This page intentionally left blank...
Page 256: ...10 14 Human Machine Interface BE1 CDS220 This page intentionally left blank...
Page 258: ...ii ASCII Command Interface BE1 CDS220 This page intentionally left blank...
Page 422: ...14 32 BESTCOMS Software BE1 CDS220 This page intentionally left blank...
Page 424: ...ii Time Current Characteristics BE1 CDS220 This page intentionally left blank...
Page 452: ...ii Terminal Communication BE1 CDS220 This page intentionally left blank...
Page 456: ...C 4 Terminal Communication BE1 CDS220 This page intentionally left blank...
Page 458: ...ii Settings Calculations BE1 CDS220 This page intentionally left blank...
Page 475: ......