![Xilinx Virtex-II Pro PPC405 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/xilinx/virtex-ii-pro-ppc405/virtex-ii-pro-ppc405_user-manual_3410279011.webp)
March 2002 Release
319
Virtex-II Pro™ Platform FPGA Documentation
1-800-255-7778
Terms
R
Book-E
An version of the PowerPC architecture designed specifically
for embedded applications.
cache block
Synonym for
cacheline
.
cacheline
A portion of a cache array that contains a copy of contiguous
system-memory addresses. Cachelines are 32-bytes long and
aligned on a 32-byte address.
clear
To write a bit value of 0.
cache set
Synonym for
congruence class
.
congruence class
A collection of cachelines with the same index.
dirty
An indication that cache information is more recent than the
copy in memory.
doubleword
Eight bytes, or 64 bits.
effective address
The untranslated memory address as seen by a program.
exception
An abnormal event or condition that requires the processor’s
attention. They can be caused by instruction execution or an
external device. The processor records the occurrence of an
exception and they often cause an
interrupt
to occur.
fill buffer
A buffer that receives and sends data and instructions between
the processor and PLB. It is used when cache misses occur and
when access to non-cacheable memory occurs.
flush
A cache or TLB operation that involves writing back a modified
entry to memory, followed by an invalidation of the entry.
GB
Gigabyte, or one-billion bytes.
halfword
Two bytes, or 16 bits.
hit
For cache arrays and TLB arrays, an indication that requested
information exists in the accessed array.
interrupt
The process of stopping the currently executing program so that
an exception can be handled.
invalidate
A cache or TLB operation that causes an entry to be marked as
invalid. An invalid entry can be subsequently replaced.
KB
Kilobyte, or one-thousand bytes.
line buffer
A buffer located in the cache array that can temporarily hold the
contents of an entire cacheline. It is loaded with the contents of
a cacheline when a cache hit occurs.
little endian
A memory byte ordering where the address of an item
corresponds to the least-significant byte.
logical address
Synonym for
effective address
.
MB
Megabyte, or one-million bytes.
memory
Collectively, cache memory and system memory.
miss
For cache arrays and TLB arrays, an indication that requested
information does not exist in the accessed array.
Содержание Virtex-II Pro PPC405
Страница 1: ...R Volume 2 a PPC405 User Manual Virtex II Pro Platform FPGA Developer s Kit March 2002 Release...
Страница 14: ...322 www xilinx com March 2002 Release 1 800 255 7778 Virtex II Pro Platform FPGA Documentation Preface R...
Страница 252: ...560 www xilinx com March 2002 Release 1 800 255 7778 Virtex II Pro Platform FPGA Documentation R...
Страница 260: ...568 www xilinx com March 2002 Release 1 800 255 7778 Virtex II Pro Platform FPGA Documentation R...
Страница 562: ...870 www xilinx com March 2002 Release 1 800 255 7778 Virtex II Pro Platform FPGA Documentation R...