LTE Multi Evaluation Measurement
R&S
®
CMW-KM5xx/-KS5xx
691
User Manual 1173.9628.02 ─ 16
<3_StatistExpired>
Reached statistical length in slots
Range:
0 to 1000
<4_OutOfTol>
Percentage of measured subframes with failed limit check
Range:
0 % to 100 %
Default unit: %
<5_Ripple1>
Max (Range 1) - Min (Range 1)
Range:
0 dB to 40 dB
Default unit: dB
<6_Ripple2>
Max (Range 2) - Min (Range 2)
Range:
0 dB to 40 dB
Default unit: dB
<7_MaxR1MinR2>
Max (Range 1) - Min (Range 2)
Range:
-40 dB to 40 dB
Default unit: dB
<8_MaxR2MinR1>
Max (Range 2) - Min (Range 1)
Range:
-40 dB to 40 dB
Default unit: dB
<9_MinR1>
Min (Range 1)
Range:
-20 dB to 20 dB
Default unit: dB
<10_MaxR1>
Max (Range 1)
Range:
-20 dB to 20 dB
Default unit: dB
<11_MinR2>
Min (Range 2)
Range:
-20 dB to 20 dB
Default unit: dB
<12_MaxR2>
Max (Range 2)
Range:
-20 dB to 20 dB
Default unit: dB
Example:
See
Usage:
Query only
Firmware/Software:
V2.0.10
V2.0.20: CALCulate commands
V2.1.25: increased maximum number of segments to 250,
added <9_MinR1> to <12_MaxR2>
V2.1.30: increased maximum number of segments to 512
V3.0.50: increased maximum number of segments to 1000
Options:
R&S CMW-KM012