![R&S CMW-KM5 Series Скачать руководство пользователя страница 456](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802456.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
456
User Manual 1173.9628.02 ─ 16
Firmware/Software:
V3.2.80
Options:
R&S CMW-KS510
Manual operation:
See
CONFigure:LTE:SIGN<i>:EBLer:CONFidence:MTTime
<Time>
Specifies a minimum test time for confidence BLER measurements.
Parameters:
<Time>
Minimum number of processed subframes
Range:
0 to 500E+3
Increment: 200
*RST:
0
Example:
See
Configuring a BLER Measurement
Firmware/Software:
V3.0.30
Options:
R&S CMW-KS510
Manual operation:
See
CONFigure:LTE:SIGN<i>:EBLer:CONFidence:LERate
<Rate>
Selects the limit error ratio for a confidence BLER measurement.
Parameters:
<Rate>
P001 | P010 | P050
P001:
0.1 %, 3GPP TS 36.521 Annex G.4
P010:
1 %, 3GPP TS 36.521 Annex G.4
P050:
5 %, 3GPP TS 36.521 Annex G.2
*RST:
P050
Example:
See
Configuring a BLER Measurement
Firmware/Software:
V3.0.30
Options:
R&S CMW-KS510
Manual operation:
See
2.6.19.3
Measurement Results
All results of the BLER measurement are retrieved via
FETCh
commands.
There are two types of
FETCh
commands:
●
FETCh:LTE:...
waits until the current measurement cycle is complete and
returns the final results of the measurement cycle.
This type of command is available for all results.
●
FETCh:INTermediate:LTE:...
returns the already available measurement
results immediately, even if the first measurement cycle is not yet complete.
Command Reference