![R&S CMW-KM5 Series Скачать руководство пользователя страница 334](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802334.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
334
User Manual 1173.9628.02 ─ 16
Example:
See
Firmware/Software:
V1.0.15.21
Manual operation:
See
"Exp. Nominal Power..., Margin"
CONFigure:LTE:SIGN<i>:RFSettings:ENPower
<ExpectedPower>
Sets the expected nominal power of the UL signal in manual mode or queries the result
if the expected nominal power is calculated automatically according to the UL power
control settings.
To configure the expected nominal power mode see
Parameters:
<ExpectedPower>
In manual mode the range of the expected nominal power can
be calculated as follows:
Range (Expected Nominal Power) = Range (Input Power) +
External Attenuation - Margin
Range:
-47 dBm to 42 dBm for the input power at the RF
COM connectors (please notice also the ranges
quoted in the data sheet)
*RST:
-20 dBm
Default unit: dBm
Example:
See
Firmware/Software:
V1.0.15.21
Manual operation:
See
"Exp. Nominal Power..., Margin"
CONFigure:LTE:SIGN<i>:RFSettings:UMARgin
<UserMargin>
Sets the margin that the R&S
CMW adds to the expected nominal power in order to
determine the reference level in manual mode. If the expected nominal power is calcu-
lated automatically according to the UL power control settings, a fix margin of 12 dB is
used instead.
The reference level minus the external input attenuation must be within the power
range of the selected input connector; refer to the data sheet.
Refer also to the following commands:
●
●
●
Command Reference