![R&S CMW-KM5 Series Скачать руководство пользователя страница 309](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802309.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
309
User Manual 1173.9628.02 ─ 16
<PCCTX1Connector> RF1C | RF1O | RF2C | RF3C | RF3O | RF4C | RFAC | RFAO |
RFBC
RF connector for the first PCC output path. Select different con-
nectors for the two PCC paths.
<PCCTX1Converter> TX1 | TX2 | TX3 | TX4
TX module for the first PCC output path. Select different mod-
ules for all output paths.
<PCCTX2Connector> RF1C | RF1O | RF2C | RF3C | RF3O | RF4C | RFAC | RFAO |
RFBC
RF connector for the second PCC output path
<PCCTX2Converter> TX1 | TX2 | TX3 | TX4
TX module for the second PCC output path
<SCCTX1Connector> RF1C | RF1O | RF2C | RF3C | RF3O | RF4C | RFAC | RFAO |
RFBC
RF connector for the first SCC output path. Select different con-
nectors for the two SCC paths.
<SCCTX1Converter> TX1 | TX2 | TX3 | TX4
TX module for the first SCC output path. Select different mod-
ules for all output paths.
<SCCTX2Connector> RF1C | RF1O | RF2C | RF3C | RF3O | RF4C | RFAC | RFAO |
RFBC
RF connector for the second SCC output path
<SCCTX2Converter> TX1 | TX2 | TX3 | TX4
TX module for the second SCC output path
Example:
See
Firmware/Software:
V3.2.50
Options:
R&S CMW-KS520
R&S CMW-KS502 for FDD / R&S CMW-KS552 for TDD
Manual operation:
See
ROUTe:LTE:SIGN<i>:SCENario:SCFading[:EXTernal]
<RXConnector>,
<RXConverter>, <TXConnector>, <TXConverter>, <IQConnector>
Activates the scenario "1 Cell - Fading - 1 RF Out" with external fading and selects the
RF connectors, RX/TX modules and digital I/Q output connector to be used. To query
the active scenario, use
Depending on the installed hardware and the active sub-instrument or instance <i>
only a subset of the described parameter values is allowed. The *RST values and the
mapping of virtual connector names to physical connectors also depend on the active
sub-instrument or instance <i>.