![R&S CMW-KM5 Series Скачать руководство пользователя страница 822](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802822.webp)
LTE SRS Measurement
R&S
®
CMW-KM5xx/-KS5xx
822
User Manual 1173.9628.02 ─ 16
Hotkey
Description
"Ref. Marker ..."
Enable or disable the reference marker and select the marker position. If sev-
eral traces can be displayed, a trace can also be selected.
"Marker 1 /2 ..."
Enable or disable marker 1 or 2 and define the marker position (absolute or rel-
ative to the reference marker).
Depending on the trace mode, a trace can also be selected.
"Select Trace Mode"
Define whether marker 1 and 2 are set to the same trace as the reference
marker (collective) or to selectable individual traces.
See also: "Markers" in the R&S
CMW user manual, chapter "System Overview"
5.3 GUI Reference
The following sections provide detailed reference information on the Graphical User
Interface (GUI) and the parameters of the "LTE SRS" measurement.
............................................................................................822
.......................................................................................822
........................................................................................... 832
5.3.1 Measurement Control
The measurement is turned on or off using the ON | OFF or RESTART | STOP keys.
See also: "Measurement Control" in the R&S
CMW user manual, chapter "System
Overview"
SRS (Softkey)
The softkey shows the current measurement state. Additional measurement substates
can be retrieved via remote control.
Remote command:
5.3.2 Parameters and Settings
The most important settings of the "LTE SRS" measurement are displayed in the mea-
surement dialog.
GUI Reference
深圳德标仪器