![R&S CMW-KM5 Series Скачать руководство пользователя страница 558](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802558.webp)
LTE Multi Evaluation Measurement
R&S
®
CMW-KM5xx/-KS5xx
558
User Manual 1173.9628.02 ─ 16
ACLR > Select ACLR
Specifies which adjacent channels shall be evaluated: 1
st
adjacent UTRA channels, 2
nd
adjacent UTRA channels or 1
st
adjacent E-UTRA channels. Any combinations are sup-
ported, including the activation of all three options in parallel.
Remote command:
3.3.5.5
Power Settings
The following "Measurement Control" parameters configure the power measurement
settings.
Fig. 3-43: Measurement control settings - power
.................................................................................. 558
Dynamics
The following parameters configure the power dynamics measurement.
Time Mask ← Dynamics
Selects the time mask for power dynamics measurements. The time masks are defined
by 3GPP. Each mask is designed for a specific sequence of powers.
"ON" and "OFF" indicate the PUCCH/PUSCH power. "SRS ON" and "SRS OFF" indi-
cate the SRS power.
●
General On / Off
: OFF - ON - OFF
See 3GPP TS 36.521, section 6.3.4.1 / 6.3.4A.1
●
PUCCH / PUSCH / SRS
: ON - SRS ON - ON
See 3GPP TS 36.101, figure 6.3.4.4-2
●
SRS blanking
: ON - SRS OFF - ON
See 3GPP TS 36.101, figure 6.3.4.4-4
See also
chapter 3.2.5.11, "Power Dynamics Limits"
Remote command:
Add. Excl. OFF Power ← Dynamics
Shifts the OFF power evaluation periods.
GUI Reference
深圳德标仪器