LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
291
User Manual 1173.9628.02 ─ 16
The full list contains 18 times n+1 values. Each block of 18 values corresponds to the
CDMA2000 band classes. Each repetition corresponds to a supported band combina-
tion:
{measured band: 0, 1, ..., 17}
used band combination 0
,
{measured band: 0, 1, ..., 17}
used band combination 1
, ...,
{measured band: 0, 1, ..., 17}
used band combination n
Via the optional parameter <Index>, you can alternatively query the list for a single
CDMA2000 band class:
{used combination: 0, 1, ..., n}
measured band <Index>
Suffix:
<number>
.
1020
Query parameters:
<Index>
BC0 | BC1 | BC2 | BC3 | BC4 | BC5 | BC6 | BC7 | BC8 | BC9 |
BC10 | BC11 | BC12 | BC13 | BC14 | BC15 | BC16 | BC17
Selects the measured CDMA2000 band class, for which the list
shall be returned.
Return values:
<Value>
OFF | ON
Without <Index>: 18 x (n+1) values
With <Index>: n+1 values
Example:
See
Querying UE Capability Report Contents
Usage:
Query only
Firmware/Software:
V3.2.80
Manual operation:
See
"Inter-RAT Need for Gaps v1020"
SENSe:LTE:SIGN<i>:UECapability:MEAS:IRNGaps:V<number>:CXRTt?
[<Index>]
Returns a list of values indicating the need for downlink measurement gaps when oper-
ating on a specific E-UTRA band combination and measuring on a specific CDMA2000
1xRTT band class.
The full list contains 18 times n+1 values. Each block of 18 values corresponds to the
CDMA2000 band classes. Each repetition corresponds to a supported band combina-
tion:
{measured band: 0, 1, ..., 17}
used band combination 0
,
{measured band: 0, 1, ..., 17}
used band combination 1
, ...,
{measured band: 0, 1, ..., 17}
used band combination n
Via the optional parameter <Index>, you can alternatively query the list for a single
CDMA2000 band class:
{used combination: 0, 1, ..., n}
measured band <Index>
Command Reference