![R&S CMW-KM5 Series Скачать руководство пользователя страница 563](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802563.webp)
LTE Multi Evaluation Measurement
R&S
®
CMW-KM5xx/-KS5xx
563
User Manual 1173.9628.02 ─ 16
This parameter can be used to prevent unwanted trigger events due to fast power var-
iations.
Remote command:
Synchronization Mode
Selects the size of the search window for synchronization - normal or enhanced.
If the trigger signal is timed accurately, the normal synchronization mode is sufficient
and should be used for performance reasons. With increasing inaccuracy of the trigger
signal timing, the search window in normal mode may be too small, resulting in a "Syn-
chronization Problem". In that case select the enhanced mode to increase the search
window size.
For "Free Run (Fast Sync)" an enhanced search window is used irrespective of this
parameter.
Remote command:
Acquisition Mode
Selects whether the R&S
CMW shall synchronize to a slot boundary or to a subframe
boundary. The parameter is relevant for "Free Run (Fast Sync)" and for list mode
measurements with Synchronization Mode = Enhanced.
Remote command:
3.3.7 Limit Settings
The "Limits" in the "Multi Evaluation Configuration" dialog define lower and/or upper
limits for the modulation, spectrum and power results. Separate limits can be set for
the individual modulation schemes or channel bandwidths.
For details see
chapter 3.2.5, "Limit Settings and Conformance Requirements"
GUI Reference
135-1095-0799