![R&S CMW-KM5 Series Скачать руководство пользователя страница 178](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802178.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
178
User Manual 1173.9628.02 ─ 16
Inactivity Timer
"On" time after reception and decoding of a PDCCH for this UE ("drx-InactivityTimer").
Remote command:
Retransmission Timer
"On" time if the UE expects a DL retransmission ("drx-RetransmissionTimer"). The
timer expires early when the retransmission is received.
Remote command:
Long DRX Cycle
Duration of one long DRX cycle (longDRX-Cycle).
If short DRX cycles are enabled, the long DRX cycle duration is always a multiple of
the short DRX cycle duration. Enabling short DRX cycles or modifying the short DRX
cycle duration modifies also the long DRX cycle duration, so that it is compatible.
Remote command:
Start Offset
Offset shifting all short and long DRX cycles (drxStartOffset).
Remote command:
DRX Short Cycle
The following settings configure optional short DRX cycles.
Enable ← DRX Short Cycle
Enables short DRX cycles.
Remote command:
Short DRX Cycle ← DRX Short Cycle
Duration of one short DRX cycle (shortDRX-Cycle).
The long DRX cycle duration is always a multiple of the short DRX cycle duration and
adapted automatically to this setting (if short cycles are enabled).
Remote command:
Short Cycle Timer ← DRX Short Cycle
Number of short DRX cycles to be processed (drxShortCycleTimer), for example after
the inactivity timer has expired.
Remote command:
GUI Reference
深圳德标仪器