![R&S CMW-KM5 Series Скачать руководство пользователя страница 794](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802794.webp)
LTE PRACH Measurement
R&S
®
CMW-KM5xx/-KS5xx
794
User Manual 1173.9628.02 ─ 16
Parameters:
<EVMwindowPos>
LOW | HIGH
*RST:
LOW
Example:
See
Specifying Additional Measurement-Specific Settings
Firmware/Software:
V2.0.10
Manual operation:
See
4.5.3.5
Power Measurement Settings
The following commands specify settings for power dynamics measurements.
CONFigure:LTE:MEAS<i>:PRACh:SCOunt:PDYNamics
<StatisticCount>
Specifies the statistic count of the measurement. The statistic count is equal to the
number of measurement intervals per single shot. Use
CONFigure:...:MEAS<i>:...:REPetition SINGleshot | CONTinuous
to
select either single-shot or continuous measurements.
See also: "Statistical Settings" in the R&S
CMW user manual, chapter "Remote Con-
trol"
Parameters:
<StatisticCount>
Number of measurement intervals
Range:
1 to 1000
*RST:
1
Example:
See
Specifying Additional Measurement-Specific Settings
Firmware/Software:
V2.0.10
Manual operation:
See
CONFigure:LTE:MEAS<i>:PRACh:POWer:HDMode
<HighDynamicMode>
Enables or disables the high dynamic mode for power dynamics measurements.
Parameters:
<HighDynamicMode> OFF | ON
*RST:
OFF
Example:
See
Specifying Additional Measurement-Specific Settings
Firmware/Software:
V2.1.25
Manual operation:
See
4.5.3.6
Trigger Settings
The following commands define the trigger parameters.
Command Reference