![R&S CMW-KM5 Series Скачать руководство пользователя страница 126](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802126.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
126
User Manual 1173.9628.02 ─ 16
The signaling application uses this information to compensate for the delay and to syn-
chronize the uplink and the downlink in spite of the delay.
Remote command:
2.4.6.2
RF Frequency
This section configures the operating band and channel/frequency for uplink and down-
link.
The uplink settings configure the center frequency of the RF analyzer. The downlink
settings configure the carrier center frequency of the generated LTE signal.
If option R&S CMW-KS525 is available, a user-defined band can be specified and
used.
For carrier aggregation scenarios, you can configure different PCC and SCC downlink
settings.
Fig. 2-50: Frequency settings
Operating Band, Channel, Frequency
.........................................................................126
......................................................................................... 127
..................................................................................... 127
...............................................................................................128
................................................................................ 128
................................................................................ 128
Operating Band, Channel, Frequency
To specify the DL and UL frequencies, select an operating band first, then enter a valid
channel number or frequency for UL or DL. The related frequency or channel number
and the parameters for the other direction are calculated automatically.
GUI Reference
深圳德标仪器