![R&S CMW-KM5 Series Скачать руководство пользователя страница 664](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802664.webp)
LTE Multi Evaluation Measurement
R&S
®
CMW-KM5xx/-KS5xx
664
User Manual 1173.9628.02 ─ 16
Usage:
Query only
Firmware/Software:
V2.0.10
FETCh:LTE:MEAS<i>:MEValuation:IEMission:SCC<no>:MARGin:CURRent:
RBINdex?
FETCh:LTE:MEAS<i>:MEValuation:IEMission:SCC<no>:MARGin:EXTReme:
RBINdex?
Return resource block indices for SCC inband emission margins. At these RB indices
the
CURRent
and
EXTReme
margins have been detected (see
and
...:EXTReme
).
Suffix:
<no>
.
1
Only SCC1 supported - suffix can be omitted
Return values:
<Reliability>
<OutOfTolerance>
Out of tolerance result, i.e. percentage of measurement inter-
vals of the statistic count for modulation measurements exceed-
ing the specified inband emission limits.
Range:
0 % to 100 %
<RBindex>
Resource block index
Range:
0 to 99
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V3.2.70
Options:
R&S CMW-KM502/-KM552 for FDD/TDD
3.5.3.24
ACLR Spectrum Results
The following commands return the results of the ACLR spectrum multi evaluation
measurement.
FETCh:LTE:MEAS<i>:MEValuation:TRACe:ACLR:CURRent?
............................................665
FETCh:LTE:MEAS<i>:MEValuation:TRACe:ACLR:AVERage?
........................................... 665
READ:LTE:MEAS<i>:MEValuation:TRACe:ACLR:CURRent?
............................................. 665
READ:LTE:MEAS<i>:MEValuation:TRACe:ACLR:AVERage?
.............................................665
FETCh:LTE:MEAS<i>:MEValuation:ACLR:CURRent?
....................................................... 665
FETCh:LTE:MEAS<i>:MEValuation:ACLR:AVERage?
.......................................................665
READ:LTE:MEAS<i>:MEValuation:ACLR:CURRent?
........................................................ 665
READ:LTE:MEAS<i>:MEValuation:ACLR:AVERage?
........................................................ 665
CALCulate:LTE:MEAS<i>:MEValuation:ACLR:CURRent?
..................................................665
CALCulate:LTE:MEAS<i>:MEValuation:ACLR:AVERage?
................................................. 665