![R&S CMW-KM5 Series Скачать руководство пользователя страница 184](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802184.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
184
User Manual 1173.9628.02 ─ 16
2.4.12.8
CQI Channel Configuration
The configuration depends on the CQI scheduling type.
●
"Fixed CQI" and "Follow WB PMI":
Uplink and downlink settings for these scheduling types can only be configured
from the main view, not from the configuration tree.
●
"Follow WB CQI", "Follow WB CQI-RI" and "Follow WB CQI-PMI-RI":
The uplink settings can only be configured from the main view, not from the config-
uration tree. The downlink settings are also contained in the configuration tree:
For a description of all parameters, see
chapter 2.4.1.7, "TTI-Based Channel Configu-
2.4.13 CQI Reporting
The following parameters configure Channel Quality Indication (CQI) reporting. The
reporting procedures are specified in 3GPP TS 36.213, section 7.2.
For scenarios without carrier aggregation, option R&S CMW-KS510 is required. For
scenarios with carrier aggregation, R&S CMW-KS512 is required.
Which reports are sent by the UE depends on the transmission mode. If you want to
see CQI, PMI and RI reports, you can use for example transmission mode 4.
Fig. 2-80: CQI reporting settings
..................................................................................185
CQI/PMI Reporting Period / Offset
..............................................................................185
Enable CQI Reporting
Enables periodic CQI reporting (Periodic) or disables CQI reporting completely (Off).
For the scheduling types "Follow...", periodic CQI reporting is enabled automatically.
GUI Reference
深圳德标仪器