![R&S CMW-KM5 Series Скачать руководство пользователя страница 269](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802269.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
269
User Manual 1173.9628.02 ─ 16
Return values:
<RSCPlower>
RSCP minimum value
Range:
-120 dBm to -25 dBm
Default unit: dBm
<RSCPupper>
RSCP maximum value
Range:
-120 dBm to -25 dBm
Default unit: dBm
<EcNOlower>
Ec/No minimum value
Range:
-24 dB to 0 dB
Default unit: dB
<EcNOupper>
Ec/No maximum value
Range:
-24 dB to 0 dB
Default unit: dB
Example:
See
Querying UE Measurement Report Contents
Usage:
Query only
Firmware/Software:
V3.0.50
Options:
R&S CMW-KS510
Manual operation:
See
SENSe:LTE:SIGN<i>:UEReport:NCELl:CDMA:CELL<no>?
Returns measurement report values for a selected CDMA2000 neighbor cell.
Suffix:
<no>
.
1..4
Selects the CDMA2000 neighbor cell
Return values:
<pilotPnPhase>
Reported pilot PN phase value
Range:
0 PN Chips to 32767 PN Chips
Default unit: PN Chips
<pilotStrength>
Reported pilot strength value
Range:
0 to 63
Example:
See
Querying UE Measurement Report Contents
Usage:
Query only
Firmware/Software:
V3.0.50
Options:
R&S CMW-KS510
Manual operation:
See
"CDMA2000 / 1xEV-DO > pilot Pn Phase, pilot Strength"
Command Reference