LTE SRS Measurement
R&S
®
CMW-KM5xx/-KS5xx
847
User Manual 1173.9628.02 ─ 16
Firmware/Software:
V2.0.20
Manual operation:
See
TRIGger:LTE:MEAS<i>:SRS:TOUT
<TriggerTimeOut>
Selects the maximum time that the R&S
CMW will wait for a trigger event before it
stops the measurement in remote control mode or indicates a trigger timeout in manual
operation mode. This setting has no influence on "Free Run" measurements.
Parameters:
<TriggerTimeOut>
Range:
0.01 s to 167772.15 s
*RST:
0.1 s
Default unit: s
Example:
See
Configuring the Trigger System
Firmware/Software:
V2.0.20
Manual operation:
See
TRIGger:LTE:MEAS<i>:SRS:MGAP
<MinTrigGap>
Sets a minimum time during which the IF signal must be below the trigger threshold
before the trigger is armed so that an IF power trigger event can be generated.
Parameters:
<MinTrigGap>
Range:
0 s to 1E-3 s
*RST:
50E-6 s
Default unit: s
Example:
See
Configuring the Trigger System
Firmware/Software:
V2.0.20
Manual operation:
See
5.5.3.4
Limits
The following command defines limits for results which characterize the power dynam-
ics of the SRS signal.
CONFigure:LTE:MEAS<i>:SRS:LIMit:PDYNamics
<Enable>, <OnPowerUpper>,
<OnPowerLower>, <OffPowerUpper>
Defines limits for the ON power and OFF power determined with the power dynamics
measurement.
Parameters:
<Enable>
OFF | ON
OFF
: disables the limit check
ON
: enables the limit check
*RST:
ON
Command Reference