![R&S CMW-KM5 Series Скачать руководство пользователя страница 798](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802798.webp)
LTE PRACH Measurement
R&S
®
CMW-KM5xx/-KS5xx
798
User Manual 1173.9628.02 ─ 16
<Peak>
Range:
0 % to 100 %
*RST:
35 %, OFF
Default unit: %
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
Example:
See
Firmware/Software:
V2.0.10
Manual operation:
See
CONFigure:LTE:MEAS<i>:PRACh:LIMit:PERRor
<RMS>, <Peak>
Defines symmetric limits for the RMS and peak values of the phase error. The limit
check fails if the absolute value of the measured phase error exceeds the specified val-
ues.
Parameters:
<RMS>
Range:
0 deg to 180 deg
*RST:
17.5 deg, OFF
Default unit: deg
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
<Peak>
Range:
0 deg to 180 deg
*RST:
35 deg, OFF
Default unit: deg
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
Example:
See
Firmware/Software:
V2.0.10
Manual operation:
See
CONFigure:LTE:MEAS<i>:PRACh:LIMit:FERRor
<FrequencyError>
Defines an upper limit for the carrier frequency error.
Parameters:
<FrequencyError>
Range:
0 ppm to 1000 ppm
*RST:
0.1 ppm, ON
Additional parameters: OFF | ON (disables the limit check | ena-
bles the limit check using the previous/default limit values)
Example:
See
Firmware/Software:
V2.0.10
Manual operation:
See
Command Reference