// Query information about the resulting aggregated bandwidth.
// Select the PCC for single-carrier mesaurements.
// *****************************************************************************
CONFigure:LTE:MEAS:CAGGregation:MODE INTRaband
CONFigure:LTE:MEAS:SCC:CBANdwidth B014
CONFigure:LTE:MEAS:CAGGregation:SCC:ACSPacing
CONFigure:LTE:MEAS:RFSettings:SCC:FREQuency?
CONFigure:LTE:MEAS:CAGGregation:FREQuency:AGGRegated:LOW?
CONFigure:LTE:MEAS:CAGGregation:FREQuency:AGGRegated:CENTer?
CONFigure:LTE:MEAS:CAGGregation:FREQuency:AGGRegated:HIGH?
CONFigure:LTE:MEAS:CAGGregation:CBANdwidth:AGGRegated?
CONFigure:LTE:MEAS:CAGGregation:MCARrier PCC
// *****************************************************************************
// Set duplex mode TDD and query the resulting frame structure type (T2).
// *****************************************************************************
CONFigure:LTE:MEAS:DMODe TDD
CONFigure:LTE:MEAS:FSTRucture?
3.4.1.2
Specifying Required Settings
// *****************************************************************************
// Specify required UE signal settings: UL/DL configuration 1,
// special subframe configuration 1, extended cyclic prefix,
// signal contains PUCCH with format 1a, physical layer cell ID 5,
// delta sequence shift value 10, no group hopping.
// *****************************************************************************
CONFigure:LTE:MEAS:MEValuation:ULDL 1
CONFigure:LTE:MEAS:MEValuation:SSUBframe 1
CONFigure:LTE:MEAS:MEValuation:CPRefix EXTended
CONFigure:LTE:MEAS:MEValuation:PFORmat F1A
CONFigure:LTE:MEAS:MEValuation:PLCid 5
CONFigure:LTE:MEAS:MEValuation:DSSPusch 10
CONFigure:LTE:MEAS:MEValuation:GHOPping OFF
3.4.1.3
Specifying Additional Measurement-Specific Settings
// *****************************************************************************
// Define stop condition (stop on limit failure), measurement mode and error
// handling, measured subframe contains only PUCCH (no automatic detection),
// network signaled value NS_10 (without CA) and CA_NS_11 (with CA),
// set no. of resource blocks filter to 10, set a channel type filter.
// *****************************************************************************
CONFigure:LTE:MEAS:MEValuation:SCONdition SLFail
CONFigure:LTE:MEAS:MEValuation:MMODe NORMal
CONFigure:LTE:MEAS:MEValuation:MOEXception ON
CONFigure:LTE:MEAS:MEValuation:TOUT 3600