LTE Multi Evaluation Measurement
R&S
®
CMW-KM5xx/-KS5xx
576
User Manual 1173.9628.02 ─ 16
●
There are two groups of
FETCh
commands. One for result retrieval per segment
and one for result retrieval over all segments. Which of the two groups is more
effective, depends on the enabled results and on the number of segments.
Minimize the number of
FETCh
commands transmitted for result query.
●
To reset the system repeatedly, use partial reset commands instead of the global
reset command
*RST
.
Example: Use
SYSTem:RESet 'LTE Meas1'
to reset the LTE measurement
instance 1.
●
To configure the same list mode settings repeatedly, use partial save/recall com-
mands:
–
Configure all list mode settings once.
–
Save the list mode settings to a file, for example to the file
ListModeLTE1.dfl
located in the directory assigned to the
@SAVE
alias:
MMEMory:STORe:ITEM 'LTE Meas:MEV:LIST',
'@SAVE\ListModeLTE1.dfl'
–
If you want to configure the same settings again, recall the stored settings:
MMEMory:LOAD:ITEM 'LTE Meas:MEV:LIST',
'@SAVE\ListModeLTE1.dfl'
3.4.2.1
Specifying Global Measurement Settings
// *****************************************************************************
// Reset
// *****************************************************************************
SYSTem:RESet 'LTE Meas1'; *OPC?
*CLS; *OPC?
// *****************************************************************************
// Define signal routing and external attenuation
// *****************************************************************************
ROUTe:LTE:MEAS:SCENario:SALone RF1C, RX1
CONFigure:LTE:MEAS:RFSettings:EATTenuation 2
// *****************************************************************************
// Specify required UE signal settings not configurable per segment:
// signal contains PUCCH with format 1a, physical layer cell ID 5,
// delta sequence shift value 10
// *****************************************************************************
CONFigure:LTE:MEAS:MEValuation:PFORmat F1A
CONFigure:LTE:MEAS:MEValuation:PLCid 5
CONFigure:LTE:MEAS:MEValuation:DSSPusch 10
3.4.2.2
Specifying List Mode Settings
// *****************************************************************************
// Define 2 segments with a length of 10 subframes each (1 radio frame),
// different expected nominal power and identical remaining settings.
// Define RB allocation manually for both segments.
Programming