![R&S CMW-KM5 Series Скачать руководство пользователя страница 290](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802290.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
290
User Manual 1173.9628.02 ─ 16
Manual operation:
See
"Inter-RAT Need for Gaps v1020"
SENSe:LTE:SIGN<i>:UECapability:MEAS:IRNGaps:V<number>:GERan?
[<Index>]
Returns a list of values indicating the need for downlink measurement gaps when oper-
ating on a specific E-UTRA band combination and measuring on a specific GERAN
band.
The full list contains 11 times n+1 values. Each block of 11 values corresponds to the
following GERAN bands: GSM 450, GSM 480, GSM 710, GSM 750, GSM 810, GSM
850, P-GSM 900, E-GSM 900, R-GSM 900, GSM 1800, GSM 1900. Each repetition
corresponds to a supported band combination:
{measured band: GSM 450, GSM 480, ..., GSM 1900}
used band combination 0
,
{measured band: GSM 450, GSM 480, ..., GSM 1900}
used band combination 1
, ...,
{measured band: GSM 450, GSM 480, ..., GSM 1900}
used band combination n
Via the optional parameter <Index>, you can alternatively query the list for a single
GERAN band:
{used combination: 0, 1, ..., n}
measured band <Index>
Suffix:
<number>
.
1020
Query parameters:
<Index>
G045 | G048 | G071 | G075 | G081 | G085 | G09P | G09E |
G09R | G18 | G19
Selects the measured GERAN band, for which the list shall be
returned.
Return values:
<Value>
OFF | ON
Without <Index>: 11 x (n+1) values
With <Index>: n+1 values
Example:
See
Querying UE Capability Report Contents
Usage:
Query only
Firmware/Software:
V3.2.80
Manual operation:
See
"Inter-RAT Need for Gaps v1020"
SENSe:LTE:SIGN<i>:UECapability:MEAS:IRNGaps:V<number>:CHRPd?
[<Index>]
Returns a list of values indicating the need for downlink measurement gaps when oper-
ating on a specific E-UTRA band combination and measuring on a specific CDMA2000
HRPD band class.
Command Reference
深圳德标仪器