LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
361
User Manual 1173.9628.02 ─ 16
CONFigure:LTE:SIGN<i>:UL:PUSCh:TPC:SINGle
<NoOfSteps>, <StepDirection>
Defines a pattern for power control of the PUSCH with the TPC setup
SINGle
. The
pattern consists of 1 to 35 up (+1 dB) or down (-1 dB) commands, followed by "con-
stant power" commands (0 dB).
For selection of the active TPC setup see
Parameters:
<NoOfSteps>
Range:
1 to 35
*RST:
1
<StepDirection>
UP | DOWN
*RST:
UP
Example:
See
Modifying Parameters for an Established Connection
Firmware/Software:
V2.0.20
V3.0.10: range increased to max 35 steps
Manual operation:
See
CONFigure:LTE:SIGN<i>:UL:PUSCh:TPC:UDPattern
<PatternLength>, <Value1>[,
<Value2>, ..., <Value20>]
Defines a pattern for power control of the PUSCH with the TPC setup
UDSingle
or
UDContinuous
.
The pattern consists of 1 to 20 TPC commands. To configure the pattern, specify the
pattern length and a corresponding number of TPC commands.
If you specify less TPC commands than required according to the pattern length, the
previously defined values are used for the remaining commands. If you specify more
TPC commands than required according to the pattern length, all values are set, but
only the values corresponding to the pattern length are used.
For selection of the active TPC setup see
Parameters:
<PatternLength>
Number of values to be considered for the pattern
Range:
1 to 20
*RST:
10
<Value1>, ...,
<Value20>
-1 | 0 | 1 | 3
Pattern values (-1 dB, 0 dB, +1 dB, +3 dB)
*RST:
1,1,1,1,1,-1,-1,-1,-1,-1,1,1,1,1,1,-1,-1,-1,-1,-1
Example:
See
Modifying Parameters for an Established Connection
Firmware/Software:
V2.0.20
Manual operation:
See
Command Reference