LTE PRACH Measurement
R&S
®
CMW-KM5xx/-KS5xx
790
User Manual 1173.9628.02 ─ 16
This command is only relevant for the standalone scenario. For the combined signal
path scenario, use:
●
●
Parameters:
<PRACHconfIndex> Range:
0 to 63 for FDD / 57 for TDD
*RST:
0
Example:
See
Specifying Required PRACH Settings
Firmware/Software:
V2.0.10
Manual operation:
See
CONFigure:LTE:MEAS<i>:PRACh:NOPReambles
<NumberPreamble>
Specifies the number of preambles to be captured per measurement interval.
Parameters:
<NumberPreamble> Range:
1 to 16
*RST:
1
Example:
See
Specifying Additional Measurement-Specific Settings
Firmware/Software:
V2.1.20
Manual operation:
See
CONFigure:LTE:MEAS<i>:PRACh:PFOFfset:AUTO
<PRACHfreqAuto>
Enables or disables automatic detection of the PRACH frequency offset. To configure
the offset manually for disabled automatic detection, see
Parameters:
<PRACHfreqAuto>
OFF | ON
*RST:
ON
Example:
See
Specifying Additional Measurement-Specific Settings
Firmware/Software:
V2.0.10
Manual operation:
See
CONFigure:LTE:MEAS<i>:PRACh:PFOFfset
<PRACHfreqOffset>
Specifies the PRACH frequency offset. This setting is only relevant if automatic detec-
tion is disabled, see
.
This command is only relevant for the standalone scenario. For the combined signal
path scenario, use