LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
115
User Manual 1173.9628.02 ─ 16
The parameter "Target" selects the handover destination. The cell icon indicates the
cell state of the currently selected destination. When you select another signaling appli-
cation, e.g. "WCDMA Sig1", the destination cell is switched on automatically and the
target cell state changes to RDY (ready for handover). For a handover to another
instrument select "No Connection" as target.
The parameter "Mobility Mode" selects the mechanism to be used for handover to
another signaling application, for example to GSM or WCDMA. Either redirection or cir-
cuit switched fallback ("MT CS Fallback") can be used. Circuit switched fallback
requires option R&S CMW-KS510. The parameter is irrelevant for a handover within
the signaling application.
The "Destination Parameters" display current settings of the selected signaling applica-
tion target, typically operating band and channels. You can modify these settings
before starting the handover. To configure the settings via remote control commands,
use the commands provided by the signaling application target. There are no special
handover commands for this purpose.
For a handover to another instrument, the "External Destination Parameters" are dis-
played instead (radio access technology and typically operating band and channel).
Configure them according to the actual configuration of the other instrument. There is
no communication between the two instruments, so the settings at both instruments
must match.
To initiate a handover, press the "Execute" button.
GUI Reference
深圳德标仪器
135-1095-0799