![R&S CMW-KM5 Series Скачать руководство пользователя страница 152](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802152.webp)
LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
152
User Manual 1173.9628.02 ─ 16
TD-SCDMA
For a TD-SCDMA (UTRA TDD) neighbor cell entry you can specify the operating band,
the channel number and the cell parameter ID.
The channel number and the TD-SCDMA reselection thresholds are written into sys-
tem information block 6.
Remote command:
2.4.11.2
Cell Reselection
The parameters in this section define cell reselection information to be transmitted in
the system information blocks SIB1 and SIB3. For detailed information refer to 3GPP
TS 36.304 and 3GPP TS 36.331.
The section is only visible if R&S CMW-KS510 is available.
Fig. 2-64: Settings for cell reselection
S IntraSearch
Threshold S
IntraSearch
for intra-frequency measurements.
The threshold is configured in dB. System information block 3 contains the configured
value divided by 2. If the checkbox is disabled, the information element is omitted in
SIB 3.
Option R&S CMW-KS510 is required.
Remote command:
S NonIntraSearch
Threshold S
nonIntraSearch
for inter-frequency and inter-RAT measurements.
The threshold is configured in dB. System information block 3 contains the configured
value divided by 2. If the checkbox is disabled, the information element is omitted in
SIB 3.
Option R&S CMW-KS510 is required.
Remote command:
ThreshServingLow
Parameter Thresh
Serving,Low
, used by the UE for reselection towards a lower priority
RAT/ frequency.
The threshold is configured in dB. System information block 3 contains the configured
value divided by 2.
GUI Reference
深圳德标仪器
135-1095-0799