CONFigure:LTE:SIGN<i>:FADing[:PCC]:FSIMulator:ILOSs:MODE
<InsertLossMode>
CONFigure:LTE:SIGN<i>:FADing:SCC:FSIMulator:ILOSs:MODE
<InsertLossMode>
Sets the insertion loss mode for PCC or SCC.
Parameters:
<InsertLossMode>
NORMal | USER
NORMal
: the insertion loss is determined by the fading profile
USER
: the insertion loss can be adjusted by the user
*RST:
NORM
Example:
See
Firmware/Software:
V3.0.20
V3.2.70: added SCC command
Options:
See relevant fading scenario
Manual operation:
See
CONFigure:LTE:SIGN<i>:FADing[:PCC]:FSIMulator:ILOSs:LOSS
<InsertionLoss>
CONFigure:LTE:SIGN<i>:FADing:SCC:FSIMulator:ILOSs:LOSS
<InsertionLoss>
Sets the insertion loss for the fading simulator for PCC or SCC.
A setting is only allowed in
USER
mode (see
CONFigure:...:FSIMulator:ILOSs:MODE
).
Parameters:
<InsertionLoss>
Range:
0 dB to 18 dB
*RST:
0 dB
Default unit: dB
Firmware/Software:
V3.0.20
V3.2.70: added SCC command
Options:
See relevant fading scenario
Manual operation:
See
SENSe:LTE:SIGN<i>:FADing[:PCC]:FSIMulator:ILOSs:CSAMples<path>?
SENSe:LTE:SIGN<i>:FADing:SCC:FSIMulator:ILOSs:CSAMples<path>?
Returns the percentage of clipped samples for one output path, for PCC or SCC.
Suffix:
<path>
.
1..2
Selects the output path. Can be omitted for transmission
schemes with only one output path.
Return values:
<ClippedSamples>
Range:
0 % to 100 %