LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
464
User Manual 1173.9628.02 ─ 16
<BLER>
Block error ratio (percentage of sent scheduled subframes for
which no ACK has been received)
Range:
0 % to 100 %
Default unit: %
<Throughput>
Average DL throughput (percentage of maximum reachable
throughput)
Range:
0 % to 100 %
Default unit: %
<DTX>
Percentage of sent scheduled subframes for which neither ACK
nor NACK has been received
Range:
0 % to 100 %
Default unit: %
Example:
See
Performing a Continuous BLER Measurement
Usage:
Query only
Firmware/Software:
V2.0.10
V2.0.20: <DTX> added
V3.0.30: INTermediate command added
V3.2.50: SCC commands added
Options:
R&S CMW-KS520
R&S CMW-KS502/-KS552 (FDD/TDD) for SCC
FETCh:LTE:SIGN<i>:EBLer[:PCC]:CQIReporting:STReam<Stream>?
FETCh:LTE:SIGN<i>:EBLer:SCC:CQIReporting:STReam<Stream>?
Returns the single results of the CQI reporting view for one PCC or SCC downlink
stream.
Suffix:
<Stream>
.
1..2
Selects the downlink stream. Can be omitted for configurations
with only one downlink stream per carrier.
Return values:
<Reliability>
<CQImedian>
Median reported CQI value
Range:
0 to 15
<RangeAbsolute>
Number of reports received for the range from median CQI - 1 to
median CQI + 1
Range:
0 to 2E+9
<RangeRelative>
<RangeAbsolute> as percentage of total number of received
reports
Range:
0 % to 100 %
Default unit: %
Command Reference
深圳德标仪器