![R&S CMW-KM5 Series Скачать руководство пользователя страница 504](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802504.webp)
LTE Multi Evaluation Measurement
R&S
®
CMW-KM5xx/-KS5xx
504
User Manual 1173.9628.02 ─ 16
3. Measure the selected segments.
4. Repeat steps 2 and 3 as often as needed.
The list mode is essentially a single-shot remote control application. When a measure-
ment is initiated in list mode, all defined segments are measured once. Afterwards the
results can be retrieved using FETCh commands.
The following remote control commands are used for list mode settings and result
retrieval:
Table 3-1: List mode commands
Parameters
SCPI commands
Activate / deactivate list mode
Segment configuration (duplex
mode, cell bandwidth, number
of subframes, ...)
Statistical length and result
activation per segment
Select trigger mode
Select range of measured seg-
ments
Retrieve results
FETCh:LTE:MEAS<i>:MEValuation:LIST:SEGMent<no>:...
FETCh:LTE:MEAS<i>:MEValuation:LIST:...
chapter 3.5.3.32, "List Mode Results (One Segment)"
chapter 3.5.3.33, "List Mode Results (All Segments,
Note that the segment number <no> for configure commands is an abso-
lute number (1..2000) while the segment number <no> for result retrieval
is a relative number within the range of measured segments (1..1000).
Example: Segment 1 to 100 configured. Segment 50 to 59 measured.
For result retrieval <no> = 1 refers to segment 50, <no> = 10 to segment
59.
The list mode can be deactivated via command (see table above) and also via the GUI:
1. Go to local using the corresponding hotkey.
The active list mode is indicated in the upper right corner of the current view by the
words "List Mode!".
2. Open the configuration dialog box and select another measurement mode in sec-
tion "Measurement Control".
General Description