![R&S CMW-KM5 Series Скачать руководство пользователя страница 619](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802619.webp)
LTE Multi Evaluation Measurement
R&S
®
CMW-KM5xx/-KS5xx
619
User Manual 1173.9628.02 ─ 16
CONFigure:LTE:MEAS<i>:MEValuation:LIST
<Enable>
Enables or disables the list mode.
Parameters:
<Enable>
OFF | ON
OFF:
Disable list mode
ON:
Enable list mode
*RST:
OFF
Example:
See
Firmware/Software:
V2.0.10
Options:
R&S CMW-KM012
Manual operation:
See
CONFigure:LTE:MEAS<i>:MEValuation:LIST:LRANge
<StartIndex>,
<NrSegments>
Select a range of measured segments. The segments must be configured using
.
Parameters:
<StartIndex>
First measured segment in the range of configured segments
Range:
1 to 2000
*RST:
1
<NrSegments>
Number of measured segments
Range:
1 to 1000
*RST:
10
Example:
See
Firmware/Software:
V2.0.10
V2.1.25: increased maximum number of segments to 250
V2.1.30: increased maximum number of segments to 512
V3.0.50: increased maximum number of segments to 1000
Options:
R&S CMW-KM012
CONFigure:LTE:MEAS<i>:MEValuation:LIST:OSINdex
<OfflineSegIndex>
Selects the number of the segment to be displayed in offline mode. The selected index
must be within the range of measured segments (see
).
Setting a value also enables the offline mode.
Parameters:
<OfflineSegIndex>
Range:
1 to 1000
*RST:
OFF
Additional parameters: OFF (disables offline mode)
Command Reference
深圳德标仪器
135-1095-0799