Replacing the Spark Igniter of the
GasTrac
(continued)
5
Mark the position of the grounding rod on the new spark igniter, using a
felt tip marker.
This index mark must end up 180° away from the burner sur-
face when the spark igniter is inserted and tightened. The electrode should be
closest to the burner surface.
6
Coat the threads of the igniter with a high-temperature conductive anti-
seize compound.
7
Carefully insert the igniter into the GasTrac.
Insert the igniter straight into
the threaded fitting. Do not bend the electrode, and do not allow the spark
igniter to touch the burner surface.
8
Screw the igniter into the threaded fit-
ting.
Tighten by hand first. Then use a
socket and ratchet to tighten the igniter
one turn or a partial turn until the index
mark on the igniter is 180° away from
the burner surface.
9
Push the boot and wire onto the spark igniter,
until you feel the boot snap
into place.
Replacement igniters are
available from Conair.
Contact Conair Parts
(800) 458 1960
From outside of the
United States, call:
(814) 437 6861
IMPORTANT:
Over tightening of the spark igniter may cause damage to the
porcelain insulator.
5-14
l M a i n t e n a n c e
Содержание HTC 120
Страница 10: ...viii l Table of Contents ...
Страница 30: ...2 14 l Description ...
Страница 35: ...Installation General Installation General l 3 5 3 I n s t a l l a t i o n ...
Страница 65: ...Installation Hard Piping Kits Installation Piping Hoses l 3 35 3 I n s t a l l a t i o n ...
Страница 80: ...3 50 l Installation Piping Hoses ...
Страница 81: ...3 I n s t a l l a t i o n Installation Main Power Connections Installation Main Power Connections l 3 51 ...
Страница 88: ...3 58 l Installation Piping Hoses ...
Страница 89: ...3 I n s t a l l a t i o n Installation Main Power Connections l 3 59 Installation Conveying Lines ...
Страница 92: ...3 62 l Installation Conveying Lines ...
Страница 93: ...Installation Water Lines 3 I n s t a l l a t i o n Installation Water Lines l 3 63 ...
Страница 115: ...Installation Compressed Air Lines 3 I n s t a l l a t i o n Installation Compressed Air Lines l 3 85 ...
Страница 124: ...3 94 l Installation Gas Piping and Exhaust Flue ...
Страница 125: ...Installation Testing 3 I n s t a l l a t i o n Installation Testing l 3 95 ...
Страница 149: ...4 O p e r a t i o n Operation l 4 7 Control Function Flow Charts continued Operation Flow Chart 1 1A 2 3 4 continued 5 ...
Страница 152: ...Control Function Flow Charts continued Setup Flow Chart 1 1B 19 38 20 34 37 4 10 l Operation continued ...
Страница 250: ...4 108 l Operation ...
Страница 286: ...5 36 l Maintenance ...