Specifications: Energ ySmart Carousel
Plus W Series Dehumidifying Dr yers
2-4
l D e s c r i p t i o n
TPDX019-0712
SPECIFICATION NOTES:
*
Dryers W600-W5000 that are central dryers do not have process heaters. Hopper Temperature Controllers (HTC’s) or GasTrac Dryers (CGT’s) are used at the hopper for heat-
ing the process air. See the Hopper Temperature Controller (HTC) and GasTrac Dryer (CGT) specification sheets for further technical information.
† Total amps listed apply to dryer only, see the Hopper Temperature Controller (HTC) or GasTrac (CGT) specification sheets for additional power requirements.
‡ Dryers running at 50 Hz will have 17% less airflow, and a 17% reduction in material throughput.
§ Total kW listed at a regeneration temperature of 350°F {177°C}. The total kW listed reflects the kW of the dryer only. It does not include any external heat source, for example
the Hopper Temperature Controller (HTC) or Gastrac Dryer (CGT).
** When drying below 150°F {66°C} a precooler is required.
†† Temperatures above or below the recommended levels may affect dryer performance. Tower, chiller or municipal water sources can be used.
‡‡ Not available in Allen Bradley models.
Specifications may change without notice. Consult a Conair sales representative for the most current information.
APPLICATION NOTES:
All dryers are supplied with an aftercooler/intercooler as standard. The aftercooler/intercooler reduces the tem-
perature of the return air from the drying hopper, improving the efficiency of the desiccant. The
aftercooler/intercooler must be connected with the proper water flow rate and temperature to attain the rated
throughput.
When to use central models
Models W600 - W5000 of Carousel Plus dryers are all configured as central dryers. Central dryers do not
have process heaters. These models should be used when drying multiple materials that require different
drying temperatures. Central models dehumidify the process air, which is then heated to the correct set-
point by a Hopper Temperature Controller (HTC) or GasTrac Dryer (CGT).
When to use additional filtration
The standard return air cartridge filter is sized for the airflow of each dryer model and is suited for most
applications. You should consider adding an optional dust collector and/or volatile trap if:
●
The material contains excessive fines. An additional dust collector or cyclone will extend time between filter
cleaning.
●
The material produces volatiles during drying which condense into a waxy or oily residue. A volatile trap will
help to protect the desiccant.
MODELS
W600
*
W800
*
W1000
*
W1300
*
W1600
*
W2000
*
W2400
*
W3200
*
W4000
*
W5000
*
Performance characteristics
(with full hopper)
Drying temperature
All models 100° - 375°F {38° - 191°C} with options
Dew point
All models -40°F {-40°C}
Dimensions
inches {cm}
A - Height
93.8 {238.3}
92.2 {134.2}
98.3 {249.7}
B - Width
49.3 {125.2}
53.9 {136.9}
58.2 {147.8}
C - Depth
72.4 {183.9}
106.6 {270.8}
123.6 {313.9}
Outlet/inlet hose diameter
8.0 {20.3}
12.0 {30.5}
12.0 {30.5}
Approximate weight
lbs {kg}
Installed
1300 {590}
1300 {590}
1400 {636}
1600 {726}
2000 {907}
Shipping
1495 {678}
1495 {678}
1515 {687}
2620 {1188}
3385 {1535}
Voltage
- Standard/Central Full load amps†
400 V/3 phase/50 Hz‡
89.2 / 34.3
89.2 / 34.3
116.6 / 34.2
152.7 / 42.9
159.4 / 49.6
194.1 / 56.8
221.7 / 57.0
282.7 / 90.5
317.0 / 97.7
371.9 / 97.4
460 V/3 phase/60 Hz
77.6 / 29.8
77.6 / 29.8
101.5 / 29.8
133.4 / 37.8
138.6 / 43.0
168.9 / 49.4
192.8 / 49.4
247.3 / 80.0
275.9 / 84.7
323.7 / 84.7
575 V/3 phase/60 Hz
62.1 / 23.9
62.1 / 23.9
81.1 / 23.8
106.6 / 30.2
110.8 / 34.4
135.1 /39.6
154.2 / 39.6
197.7 / 64.0
220.6 / 67.8
258.7 / 67.7
380 V/3 phase/60 Hz‡‡
93.9 / 36.1
93.9 / 36.1
122.7 / 36.0
160.7 / 45.2
167.8 / 52.2
204.3 / 59.8
233.4 / 60.0
297.6 / 95.3
333.7 / 102.8
391.5 / 102.5
Total kilowatts
§ kW {BTU/min} 53 {3017} /
53 {3017} /
72 {4098} /
95 {5407} /
95 {5407} /
114 {6489} /
133 {7570} /
152 {8652} /
190 {10809} / 228 {12972} /
15 {854}
15 {854}
15 {584}
19 {1081}
19 {1081}
19 {1081}
19 {1081}
38 {2157}
38 {2157}
38 {2157}
Water requirements
{for aftercooler/intercooler or optional precooler}**
Recommended temperature††
45° - 85°F {7° - 29°C}
45° - 85°F {7° - 29°C}
45° - 85°F {7° - 29°C}
Water flow gal./min. {liters/min.}
6 - 25 {22.7 - 94.6}
12 - 40 {45.4 - 151.4}
15 - 50 {56.8 - 189.3}
Water connections NPT
1 1/2 inch NPT
1 1/2 inch NPT
1 1/2 inch NPT
Содержание HTC 120
Страница 10: ...viii l Table of Contents ...
Страница 30: ...2 14 l Description ...
Страница 35: ...Installation General Installation General l 3 5 3 I n s t a l l a t i o n ...
Страница 65: ...Installation Hard Piping Kits Installation Piping Hoses l 3 35 3 I n s t a l l a t i o n ...
Страница 80: ...3 50 l Installation Piping Hoses ...
Страница 81: ...3 I n s t a l l a t i o n Installation Main Power Connections Installation Main Power Connections l 3 51 ...
Страница 88: ...3 58 l Installation Piping Hoses ...
Страница 89: ...3 I n s t a l l a t i o n Installation Main Power Connections l 3 59 Installation Conveying Lines ...
Страница 92: ...3 62 l Installation Conveying Lines ...
Страница 93: ...Installation Water Lines 3 I n s t a l l a t i o n Installation Water Lines l 3 63 ...
Страница 115: ...Installation Compressed Air Lines 3 I n s t a l l a t i o n Installation Compressed Air Lines l 3 85 ...
Страница 124: ...3 94 l Installation Gas Piping and Exhaust Flue ...
Страница 125: ...Installation Testing 3 I n s t a l l a t i o n Installation Testing l 3 95 ...
Страница 149: ...4 O p e r a t i o n Operation l 4 7 Control Function Flow Charts continued Operation Flow Chart 1 1A 2 3 4 continued 5 ...
Страница 152: ...Control Function Flow Charts continued Setup Flow Chart 1 1B 19 38 20 34 37 4 10 l Operation continued ...
Страница 250: ...4 108 l Operation ...
Страница 286: ...5 36 l Maintenance ...