Cleaning the Combustion Filter of
the GasTrac
You must clean the combustion air intake filter periodically. A clogged filter
reduces air flow through the combustion circuit, which reduces burner efficiency
and heat output.
To clean the filter:
1
Stop the GasTrac.
Press the red
“STOP” button, then press the rocker
switch to “OFF”.
2
Disconnect and lock out the main power.
3
Remove the filter shroud.
Remove the wing
nut and washer that holds the shroud in place.
Lift the shroud up and off.
4
Remove the filter.
Remove the wing nut and
washer that holds the filter in place. Lift the
filter up and off.
5
Clean the filter.
Vacuum debris from the filter
using vacuum.
6
Reassemble.
Repeat Steps 3 and 4 in reverse order to replace the filter.
ON
O
O
FF
Replacement filters are
available from Conair.
Contact Conair Parts
(800) 458 1960
From outside of the
United States, call:
(814) 437 6861
CAUTION: Wear eye protection.
If you use compressed air to
clean the equipment,
you must wear eye protection
and
observe all OSHA and other safety regulations pertaining to
the use of compressed air.
Содержание HTC 120
Страница 10: ...viii l Table of Contents ...
Страница 30: ...2 14 l Description ...
Страница 35: ...Installation General Installation General l 3 5 3 I n s t a l l a t i o n ...
Страница 65: ...Installation Hard Piping Kits Installation Piping Hoses l 3 35 3 I n s t a l l a t i o n ...
Страница 80: ...3 50 l Installation Piping Hoses ...
Страница 81: ...3 I n s t a l l a t i o n Installation Main Power Connections Installation Main Power Connections l 3 51 ...
Страница 88: ...3 58 l Installation Piping Hoses ...
Страница 89: ...3 I n s t a l l a t i o n Installation Main Power Connections l 3 59 Installation Conveying Lines ...
Страница 92: ...3 62 l Installation Conveying Lines ...
Страница 93: ...Installation Water Lines 3 I n s t a l l a t i o n Installation Water Lines l 3 63 ...
Страница 115: ...Installation Compressed Air Lines 3 I n s t a l l a t i o n Installation Compressed Air Lines l 3 85 ...
Страница 124: ...3 94 l Installation Gas Piping and Exhaust Flue ...
Страница 125: ...Installation Testing 3 I n s t a l l a t i o n Installation Testing l 3 95 ...
Страница 149: ...4 O p e r a t i o n Operation l 4 7 Control Function Flow Charts continued Operation Flow Chart 1 1A 2 3 4 continued 5 ...
Страница 152: ...Control Function Flow Charts continued Setup Flow Chart 1 1B 19 38 20 34 37 4 10 l Operation continued ...
Страница 250: ...4 108 l Operation ...
Страница 286: ...5 36 l Maintenance ...