SKYROS Corporation VideoNet 8.4 User guide
250
Now the schedule is «programmed» according to the task
F-G
.
Attention!
It is important to understand that the system doesn’t start activating
reactions (this concerns only this example) untill system operator presses
Commands
button and select
switch searchlight
button in the event list opened
(
4.1.5
section). You can also configure operator’s access rights to this button
control (it is performed on the
Screen
panel, refer to
3.3.4
section). In detail
creating users and groups, and security policies configuring for them are
described in the
chapter 3.6.
Example 4
. «Programming» system scheduler. Exceed of audio signal
volume detecting.
It is necessary:
H
. to detect exceed of audio signal allowable level from Microphone 1 from
22.00 till 06.00 according to detection parameters settings of preset by sector 3,
regardless of whether the system is armed or disarmed.
(Microphone 1; Preset 3 are before added and configured).
I
. if
extraneous noise
is detected in sector 3, it is necessary to start audio recording
from Microphone 1, video recording by Camera 2 and to send notification about
alarm in sector 3 to all remote computers.
H
.
1. Add time interval event in a new task and specify time interval from 22.00 till
06.00.
2. Add
enable detector
reaction for the event, specify microphone-detector –
Microphone 1 in the reaction properties and clear
work only if system is
armed
check-box (microphone adding into system configuration is performed
on the
Device
panel,
3.1.2.2
section).
3. Add
load detector preset
reaction and specify microphone-detector –
Microphone 1 and preset, according to which the microphone will detect
sound – preset by sector 3, in the reaction properties (presets adding is
performed on the
Detection
panel,
3.2.2
section).
I
. Now you are ready to go to
exceed of audio signal volume detected
event
configuring.
4. Create new
task
and add
exceed of audio signal volume detected
event into
it. Specify microphone-detector – Microphone 1 in the event properties. This
microphone will detect exceed of audio signal allowable level.
5. Add
video/audio data recording
reaction into the task and specify recording
function 1, according to parameters of which recording will be performed, in
the reaction properties (function 1 must contain Microphone 1 and Camera 1
as sources). Adding and configuring parameters of recording function is
performed on the
Recording
panel (refer to
chapter 3.5
).
6. Add
notification of remote computers
reaction into the task, specify message
type as custom with parameter 3 and select send notifications to all computers
option.
So, you have programmed system behaviour in response to detecting the fact of
extraneous noise
in sector 3 by Microphone 1.
In case you have performed all the steps properly, you’ll have the following in the
task tree: