SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
95
2 Parameters
2.2 List of parameters
Notice:
Information on Gn_STW/Gn_ZSW should be taken from the corresponding product documentation.
Note:
The signal source for the encoder control word is set with p0480.
Description:
Sets the input terminal to connect probe 1.
Value:
0:
No meas probe
21:
DI 1 (X07.2)
23:
DI 3 (X08.2)
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: p0489, p0490
Note:
DI: Digital Input
Description:
Sets the input terminal to connect probe 2.
Value:
0:
No meas probe
21:
DI 1 (X07.2)
23:
DI 3 (X08.2)
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: p0488, p0490
Note:
DI: Digital Input
Description:
Setting to invert the digital input signals to connect a measuring probe or an equivalent zero mark.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Request function 1
Yes
No
-
01
Request function 2
Yes
No
-
02
Request function 3
Yes
No
-
03
Request function 4
Yes
No
-
04
Request command bit 0
Yes
No
-
05
Request command bit 1
Yes
No
-
06
Request command bit 2
Yes
No
-
07
Flying measurement mode/search for
reference mark
Flying measurement
Reference marks
-
13
Request absolute value cyclic
Yes
No
-
14
Request parking encoder
Yes
No
-
15
Request acknowledge encoder fault
Yes
No
-
p0488[0...2]
Measuring probe 1 input terminal / Meas probe 1 inp
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 23
0
p0489[0...2]
Measuring probe 2 input terminal / Meas probe 2 inp
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 23
0
p0490
Invert measuring probe or equivalent zero mark / Pr or ZM_equiv inv
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4740
Min Max
Factory
setting
- - 0000
bin