SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
425
2 Parameters
2.2 List of parameters
Description:
Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Note:
For a value = 9999999, the following applies: The read operation is still running.
Description:
Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Dependency:
Refer to: p1000
Note:
For a value = 9999999, the following applies: The read operation is still running.
Description:
Displays the ACX file saved in the appropriate directory in the non-volatile memory.
Dependency:
Refer to: p1500
Note:
For a value = 9999999, the following applies: The read operation is still running.
Description:
Displays the macro currently being executed on the drive object.
Dependency:
Refer to: p0015, p1000, p1500, r8570, r8571, r8572, r8573
Description:
Sets the configuration for the content of identification and maintenance 4 (I&M 4, p8809).
Value:
0:
Standard value for I&M 4 (p8809)
1:
User value for I&M 4 (p8809)
Dependency:
For p8805 = 0, if the user writes at least one value in p8809[0...53], then p8805 is automatically set to = 1.
When p8805 is reset = 0, then the content of the factory setting is set in p8809.
r8571[0...39]
Macro Binector Input (BI) / Macro BI
Access level:
4
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
r8572[0...39]
Macro Connector Inputs (CI) for speed setpoints / Macro CI n_set
Access level:
4
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
r8573[0...39]
Macro Connector Inputs (CI) for torque setpoints / Macro CI M_set
Access level:
4
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
r8585
Macro execution actual / Macro executed
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
p8805
Identification and maintenance 4 configuration / I&M 4 config
CU240D-2_PN
CU240D-2_PN_F
CU250D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
U, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 1 0