2 Parameters
2.2 List of parameters
SINAMICS G120D
468
List Manual (LH14), 01/2016, A5E33842313
Notice:
For bit 07:
An internal event is displayed if a STOP A ... F is active.
The signal state behaves in an opposite way to the PROFIsafe Standard.
Note:
This parameter is only supplied with actual values if SI Motion functions are active. For Safety Integrated Basic
Functions (STO), the value is equal to zero.
Description:
Enters the Safety Integrated password.
Dependency:
Refer to: F01659
Note:
It is not possible to change Safety Integrated parameters until the Safety Integrated password has been entered.
Description:
Enters a new Safety Integrated password.
Dependency:
A change made to the Safety Integrated password must be acknowledged in the following parameter:
Refer to: p9763
Description:
Acknowledges the new Safety Integrated password.
Dependency:
Refer to: p9762
Note:
The new password entered into p9762 must be re-entered in order to acknowledge.
p9762 = p9763 = 0 is automatically set after the new Safety Integrated password has been successfully
acknowledged.
Description:
Displays the time remaining until the next dynamization and testing of the safety motion monitoring functions
integrated in the drives.
The signal source to initiate the forced checking procedure is parameterized in p9705.
Dependency:
Refer to: p9705
Refer to: C01798
p9761
SI password input / SI password inp
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C, T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2800
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
p9762
SI password new / SI password new
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2800
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
p9763
SI password acknowledgment / SI ackn password
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
2800
Min Max
Factory
setting
0000 hex
FFFF FFFF hex
0000 hex
r9765
SI Motion forced checking procedure remaining time (processor 1) /
SI Mtn dyn rem P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- [h]
- [h]
- [h]