![Siemens SINAMICS G120D CU240D-2 DP Manual Download Page 448](http://html.mh-extra.com/html/siemens/sinamics-g120d-cu240d-2-dp/sinamics-g120d-cu240d-2-dp_manual_381563448.webp)
2 Parameters
2.2 List of parameters
SINAMICS G120D
448
List Manual (LH14), 01/2016, A5E33842313
Description:
Displays the first index of the signal source being searched for.
The signal source to be searched for is set in p9484 (BICO-coded) and the search result is specified using the
number (r9485) and the first index (r9486).
Dependency:
Refer to: p9484, r9485
Note:
The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
Description:
Sets the enable signals for the safe motion monitoring.
Dependency:
Refer to: F01682, F01683
Note:
For bit 30 = 1, PROFIsafe telegram 31 must be configured in the F host.
A change only becomes effective after a POWER ON.
SDI: Safe Direction (safe motion direction)
SLS: Safely Limited Speed / SG: Safely reduced speed
SOS: Safe Operating Stop / SBH: Safe operating stop
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
Description:
Sets the function specification for the safe motion monitoring.
Value:
1:
Safety without encoder with braking ramp (SBR)
3:
Safety without encoder with accel_monitoring(SAM) / delay time
Dependency:
Refer to: C01711
Description:
Sets the function configuration for safe motion monitoring.
r9486
BICO interconnections signal source search first index / BICO S_src srchIdx
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - -
p9501
SI Motion enable safety functions (Control Unit) / SI Mtn enable CU
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
-
-
0000 0000 0000 0000 0000 0000 0000
0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Enable SI Motion
Enable
Inhibit
-
16
Enable SSM (n < nx) hysteresis and filtering Enable
Inhibit
2823
17
Enable SDI
Enable
Inhibit
2824
30
Enable F-DI in PROFIsafe telegram
Enable
Inhibit
-
p9506
SI Motion function specification (processor 1) / SI Mtn fct_spc P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
1 3 1
p9507
SI Motion function configuration (processor 1) / SI Mtn config P1
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
CU250D-2_DP_F
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(95)
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
- - 0011
bin