2 Parameters
2.2 List of parameters
SINAMICS G120D
514
List Manual (LH14), 01/2016, A5E33842313
Description:
Display parameter for quotients Y = X1/X2, integer number quotients YIN, and division remainder MOD = (Y - YIN) x
X2 of instance DIV 1 of the divider.
Index:
[0] = Quotient Y
[1] = Integer number quotient YIN
[2] = Div remainder MOD
Description:
Display parameter for the signal QF that the divisor X2 of instance DIV 1 of the divider is zero.
X2 = 0.0 => QF = 1
Description:
Setting parameter for the run-time group in which instance DIV 1 of the divider is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance DIV 1 within the run-time group set in p20126.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source of the input quantity X of instance AVA 0 of the absolute value generator with sign evaluation.
r20124[0...2]
CO: DIV 1 quotient / DIV 1 quotient
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
-
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7222
Min Max
Factory
setting
- - -
r20125
BO: DIV 1 divisor is zero QF / DIV 1 divisor=0 QF
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7222
Min Max
Factory
setting
- - -
p20126
DIV 1 run-time group / DIV 1 RTG
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7222
Min Max
Factory
setting
5 9999
9999
p20127
DIV 1 run sequence / DIV 1 RunSeq
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7222
Min Max
Factory
setting
0 32000
310
p20128
CI: AVA 0 input X / AVA 0 input X
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
U32 / FloatingPoint32
Can be changed:
T
Scaling:
PERCENT
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7224
Min Max
Factory
setting
- - 0