SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
407
2 Parameters
2.2 List of parameters
If value = 3:
The value in XIST1_ERW is reset after a 0/1 edge via binector input p4655 when passing the next zero mark.
Description:
Display and connector output for the actual value XIST1_ERW.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: p4652, r4654, p4655
Description:
Display and binector output to reset XIST1_ERW.
Dependency:
Refer to: p4652, r4653, p4655
Note:
The reset of XIST1_ERW is initiated via binector input p4655.
Binector output r4654 is reset with a 0 signal from binector input p4655.
Description:
Sets the signal source to reset XIST1_ERW (CO: r4653).
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency:
Refer to: p4652, r4653, r4654
Note:
The reset of XIST1_ERW depends on the selected mode (p4652).
Description:
Sets the permissible tolerance in encoder pulses for the zero mark distance in the context of zero mark monitoring.
Causes fault F3x100 to appear less frequently.
Dependency:
Refer to: F31100
r4653[0...2]
CO: XIST1_ERW actual value / XIST1_ERW actval
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4750
Min Max
Factory
setting
- - -
r4654.0...16
CO/BO: XIST1_ERW status / XIST1_ERW stat
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4750
Min Max
Factory
setting
- - -
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Encoder 1 XIST1_ERW reset
High
Low
-
08
Encoder 2 XIST1_ERW reset
High
Low
-
16
Encoder 3 XIST1_ERW reset
High
Low
-
p4655[0...2]
BI: XIST1_ERW reset signal source / XIST1_ERW resS_src
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
4750
Min Max
Factory
setting
- - 0
p4680[0...n]
Zero mark monitoring tolerance permissible / ZM_monit tol perm
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
C(4)
Scaling:
-
Dyn. index:
EDS, p0140
Unit group:
-
Unit selection:
-
Func. diagram:
-
Min Max
Factory
setting
0 1000
4