SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
517
2 Parameters
2.2 List of parameters
Description:
Setting parameter for pulse duration T in milliseconds of instance MFP 0 of the pulse generator.
Description:
Display parameter for output pulse Q of instance MFP 0 of the pulse generator.
Description:
Setting parameter for the run-time group in which the instance MFP 0 of the pulse generator is to be called.
Value:
5:
Run-time group 5
6:
Run-time group 6
9999: Do not calculate
Description:
Setting parameter for the run sequence of instance MFP 0 within the run-time group set in p20141.
Note:
The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description:
Sets the signal source for the input pulse I of instance MFP 1 of the pulse generator.
Description:
Setting parameter for pulse duration T in milliseconds of instance MFP 1 of the pulse generator.
p20139
MFP 0 pulse duration in ms / MFP 0 pulse_dur ms
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7230
Min Max
Factory
setting
0.00 5400000.00
0.00
r20140
BO: MFP 0 output Q / MFP 0 output Q
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Unsigned32
Can be changed:
-
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7230
Min Max
Factory
setting
- - -
p20141
MFP 0 run-time group / MFP 0 RTG
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Integer16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7230
Min Max
Factory
setting
5 9999
9999
p20142
MFP 0 run sequence / MFP 0 RunSeq
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
Unsigned16
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7230
Min Max
Factory
setting
0 32000
370
p20143
BI: MFP 1 input pulse I / MFP 1 inp_pulse I
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
U32 / Binary
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7230
Min Max
Factory
setting
- - 0
p20144
MFP 1 pulse duration in ms / MFP 1 pulse_dur ms
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level:
3
Calculated:
-
Data type:
FloatingPoint32
Can be changed:
T
Scaling:
-
Dyn. index:
-
Unit group:
-
Unit selection:
-
Func. diagram:
7230
Min Max
Factory
setting
0.00 5400000.00
0.00