S
IN
A
MICS
G1
20D
List Manual (LH
14)
, 01
/2016
, A5E338423
13
63
3
3
F
un
ction dia
g
ra
ms
3.
5
C
om
m
u
nica
tio
n
PRO
F
Id
rive
(
P
ROFIBUS/PROFINET
),
EtherNet/
IP
F
ig.
3
-32
24
68 – PROF
Id
rive -
rece
ive te
legra
m
, free
in
terconn
ecti
on via BIC
O
(p09
22
=
999
)
- 2468 -
Function diagram
8
7
6
5
4
3
2
1
fp_2468_97_61.vsd
PROFIdrive (PROFIBUS/PROFINET), EtherNet/IP
SINAMICS G120D
09.12.2015
V4.7.6
PROFIdrive - Receive telegram, free interconnection via BICO (p0922 = 999)
...
...
1
0
1
1
0
1
1
0
1
1
0
1
PROFINET
PROFIBUS
PROFIdrive
receive telegram
Header
Data
Trailer
PZD receive word 1
PZD receive word 2
PZD receive word 3
PZD receive word 4
PZD receive word 5
PZD receive word 6
In order to maintain the PROFIdrive profile, receive word 1 must be used as control word (STW1)
(due to bit 10 "control requested").
Using the connector-binector converters, the bits can be extracted from two of the PZD receive words 5 to 12 and used as binectors.
The following representation applies for words: 4000 hex = 100 %.
The reference variables p200x apply for the ongoing interconnection (100 % -> p200x).
The following applies for temperature values: 100 °C -> 100 % = 4000 hex, 0 °C -> 0 %.
Reference quantities for further
interconnection
p200x
2 connector-binector converter
Con/bin outp
r2094
Con/bin outp inv
p2098 [0].0
Con/bin outp inv
p2098 [0].15
Con/bin outp inv
p2098 [1].0
Con/bin outp inv
p2098 [1].15
Con/bin S_src
(0)
p2099[1]
Con/bin S_src
(0)
p2099[0]
r2050
PZD recv word
[0]
r2050
PZD recv word
[1]
r2050
PZD recv word
[2]
r2050
PZD recv word
[3]
r2050
PZD recv word
[4]
r2050
PZD recv word
[5]
Con/bin outp
r2094.15
Con/bin outp
r2095.0
Con/bin outp
r2095.15
.0
PZD1 recv bitw
r2090.0
PZD1 recv bitw
r2090.15
PZD2 recv bitw
r2091.0
PZD2 recv bitw
r2091.15
PZD receive word 7
PZD receive word 8
r2050
PZD recv word
[6]
r2050
PZD recv word
[7]
...
PZD3 recv bitw
r2092.0
PZD3 recv bitw
r2092.15
...
PZD4 recv bitw
r2093.0
PZD4 recv bitw
r2093.15
PZD receive word 9
PZD receive word 10
PZD receive word 12
PZD receive word 12
r2050
PZD recv word
[8]
r2050
PZD recv word
[9]
r2050
PZD recv word
[10]
r2050
PZD recv word
[11]
r2060
PZD recv DW
[2]
r2060
PZD recv DW
[3]
r2060
PZD recv DW
r2060
PZD recv DW
[5]
r2060
PZD recv DW
[6]
r2060
PZD recv DW
[4]
[7]
r2060
PZD recv DW
[8]
r2060
PZD recv DW
[9]
r2060
PZD recv DW
[10]
r2060
PZD recv DW
[0]
r2060
PZD recv DW
[1]
Every PZD word can be assigned a word or a double word. Only one of the 2 interconnection parameters r2050 or r2060 can have a value <> 0 for a PZD word.
When interconnecting a connector output multiple times all the connector inputs must have either Integer or FloatingPoint data type.
<1>
<4>
<4>
<4> <5>
<3>
<2>
<2>
<5>
<4>
<3>
<2>
<1>